IEC 62619 · 17 Sep 2026
What Equipment Is Needed for IEC 62619 Testing?
A laboratory-planning guide for industrial lithium cells, modules and battery packs.
There is no single IEC 62619 tester. A compliant laboratory combines electrical, thermal and mechanical equipment selected around the test object and applicable clauses.
Start with the test object
Cell and pack laboratories have radically different voltage, current, power, enclosure and chamber requirements. Define cell, module, pack or battery system before specifying any instrument.
- Cell cycler: typically low voltage with 100–500A capability for large LFP cells
- Pack cycler: potentially hundreds of volts and kilowatts
- Safety enclosure sized for the stored energy and expected failure mode
Battery charge and discharge equipment
A programmable battery cycler prepares SOC and performs controlled CC/CV charge, discharge, capacity and energy measurement. For a 314Ah cell, 0.5C is 157A, 1C is 314A and 2C is 628A, so current is selected from the required test rate—not capacity alone.
Short-circuit and abnormal charging
The short-circuit system must be designed for maximum prospective fault current, with a low-resistance path, high-current switching, current, voltage and temperature acquisition, remote operation and emergency shutdown. Abnormal charge testing also requires controlled power delivery and independent protection.
Environmental and thermal equipment
Temperature chambers control preconditioning and test temperature. Specify range, stability, volume, ramps, airflow, feedthroughs and safety ventilation. Thermal-abuse work can additionally require heaters, thermocouples, infrared measurement and engineered exhaust.
Mechanical abuse and measurement
Depending on the applicable program, laboratories may need crush, impact and vibration systems plus synchronized voltage, current and temperature acquisition. Fixtures, force range, displacement, sampling rate and remote control must match the test object.
IEC 62619 equipment checklist
Translate every relevant clause into a matrix covering test object, sample count, SOC, electrical limits, temperature, trigger, duration, measurements, acceptance criteria and equipment. Confirm the matrix with the selected certification body before procurement.
- Battery cycler
- Short-circuit tester
- Environmental chamber
- Thermal and mechanical abuse systems
- High-speed DAQ and temperature logging
- Ventilated safety chamber
Continue the technical cluster